Find Test Instrument For Use With Oscillometric Non-invasive Blood, Nibp Simulator, Contec Ms400 Nibp Simulator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Home care equipments > Blood pressure monitor > CONTEC MS200 blood pressure simulator NIBP Simulator

CONTEC MS200 blood pressure simulator NIBP Simulator

Product Description

CONTEC MS200 blood pressure simulator NIBP Simulator
Products Description
Warranty Service
1 year
After-sales service
Online technical support
Origin
Jiangsu, China
Size (L x W x H)
27 cm x 26.5 cm x 13.2 cm
Display
65k colors 4.3 inch TFT Display, brightness can be changed.
Power
AC100 - 240 V 50/60 Hz, 60 VA
Features
1. Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
2. Build-in pump provides pressure source with leak and pressure relief tests
3. NIBP simulations for both arm and wrist cuffs.
4. Provides adult,neonate, eight variations patients conditions,user-defined simulations.
5. Provides arrhythmias,respiratory artifact simulations.
6. Built-in air chamber to simulate adult and neonate cuff.
7. 65k colors,4.3" LCD display.
Parameters:
Technical index
* Pressure measurement
Units:mmHg,kPa,cmH2O,inH2O,psi
Range:0mmHg-400mmHg
Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi
Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg;
301-400 mmHg:±2%of reading
* Pressure Generator
Static Pressure Range:50 mmHg-400 mmHg
Resolution:1mmHg
Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
* Internal leak rate
<2 mmHg per minute, with a minimum volume of 300 cc
* Pressure Leak Test
Pressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time
pressures.Leak rate displayed after 10 seconds.
* Pressure Relief Test
Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure.
* Standard BP Simulations
Preset blood pressure:
1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68
2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65
3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60
4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55
5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75
6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71
7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69
* Patient Conditions
BP Simulations
Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68
Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50
Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00
Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40
Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50
Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40
Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40
Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10
* Arrhythmia Simulations
Premature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs
* Respiratory Artifacts
Spontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation
* Neonate simulations
User can select External or Internal Neonate;
1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11
2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10
3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10
4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10
* Wrist simulations
1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50
2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50
3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50
* User-Defined simulations
Allows the operator to define blood pressure simulations.
Systolic(mmHg) 20-250
Diastolic(mmHg) 10-200
Heart Rate,(bpm) 30-250
Pulse Volume,(cc) 0.1-2.4
* Simulant characteristics
The maximum pulse volume:2.4cc
The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc.
Internal Adult cuff volume:20cc
Internal neonate cuff volume:300cc
Blood pressure units: mmHg,kPa
Heart Rate Accuracy:±1BPM
Patient Conditions:
Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM
Mild exercise±1.5%±1BPM
Strenuous exercise±3%±1BPM
* Display
65k colors 4.3 inch TFT Display, brightness can be changed.
* Power
AC100 - 240 V 50/60 Hz, 60 VA
* Environmental Conditions
Working temperature: 15℃ to 40℃(59℉ to 104℉)
Storage temperature: -20℃ to +65℃(-4℉ to +149℉)
Relative humidity: < 90%,No condensation.
* Size (L x W x H)
27 cm x 26.5 cm x 13.2 cm
* Weight
About 4kg

More Products
Company View
Certifications
Packaging & Shipping
FAQ

Contact us if you need more details on Test Instrument For Use With Oscillometric Non-invasive Blood. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Nibp Simulator、Contec Ms400 Nibp Simulator. If these products fail to match your need, please contact us and we would like to provide relevant information.